P-0044
5V/5A 27W power supply with interchangeable plug standards
SKU: P-0044
Description
A power supply with interchangeable plug standards, supporting US, UK, EU, and AU standards. This product belongs to the 30W series, which does not mean it has a 30W power rating. Instead, it indicates a series of products with power ratings below 30W.
SPECIFICATION
- Type specification: P-0044-PD30W1C 5V5A/9V3A/12V2.25A/15V1.8A
- Scope: SMPS Adaptor(Wall mount) mechanical and environmental specifications of a SMPS, the power supplyprovides 27W continuous output power. The power supply shall meet the RoHS requirements
Input Characteristics
- Input Voltage & Frequency
| specifications | Minimum | Rating | Maximum |
|---|---|---|---|
| Input Voltage | 90Vac | 100Vac~240Vac | 264Vac |
| Input Frequency | 47Hz | 60Hz/50Hz | 60Hz |
- Inrush Current (cold start @ 120V AC)
No damage for 120V/50Hz at cold start (25℃)
- Average Efficiency
While input 110-240Vac ,the average efficiency is more than85.4% .The test point is at 25%,50%,75%and100%of max load respectively.
- Standby power
Standby power ≤1W @ 230VAC/50Hz.
- Cooling
Natural convection
- Mean Time Between Failure(MTBF)
The MTBF for the power adapter shall equal or exceed 10,000 hours when operated at full rated loadinanambienttemperature of 25 degree C.
- Output Characteristics
| Item | Minimum | Nominal | Maximum |
|---|---|---|---|
| OUTPUT voltage Type-C | 4.75V | 5V | 5.25V |
| 8.55V | 9V | 9.45V | |
| 11.4V | 12V | 12.6V | |
| 14.25V | 15V | 15.75V | |
| Full-load current Type-C | PDO:5V5A/9V3A/12V2.25A/15V1.8A | ||
| Total power Type-C | 27W | ||
| Fast charging protocol | Customized Protocol |
Ripple & Noise: Tested by a oscilloscope using 20MHz bandwidth and the output is paralleled a 0.1uFceramiccapacitor and a 47uF electrolysis capacitor.
Protection Requirements
- Over Current Protection: OCP Point Limited: 110%-300% auto restart
The output shall hiccup when the over current applied to the output , and shall be self-recovery whenthefaultcondition is removed
- Short Circuit Protection
The input power shall decrease when the output is short to GND, the power supply shall not damage, andshallbeself-recovery when the fault condition is removed.
Environment Requirements
- Operating Temperature and Relative Humidity: 0℃ to +40℃ 20%RH to 80%RH @ Sea level shall below or no more than2000M
- Storage Temperature and Relative Humidity: -30℃ to +70℃ 10%RH to 90%RH(non-condensing)@ Sea level shall below 10000M
- Vibration: 10 to 300Hz sweep at a constant acceleration of 1.0G(Breadth: 3.5mm) for 1Hour for each of the perpendicularaxes X, Y, Z
EMC Standards & Safety Standards / EMC
- EMC Standards/EMC
| EN 55022 | EN 55022 | CISPR 22 | CISPR22 |
| EN 61000-3-2 | EN 61000-3-2 | EN 61000-4-2 | EN 61000-4-2 |
| EN 61000-4-5 | EN 61000-4-5 | EN 61000-4-8 | EN 61000-4-8 |
| EN 61000-4-11 | J55022 |
- Safety Standards
| ! Country | Type | Standard |
|---|---|---|
| ETL | USA | UL62368 |
| GBR | UKCA-LVD | EN IEC 61558 |
| CE | Europe | EN60950-1 |
| Japan | PSE | J60950 |
- Ielectric Strength(Hi-pot): Primary to Secondary:3000Vac / 5mA / 60 seconds (3 seconds for production)
- Leakage Current: 0.25mA max. at 240Vac / 50Hz input
- Insulation Resistance: 100MΩ min. @ primary to secondary add a 500Vdc test voltage
Reliability Requirements
- Burn-in: The power supply shall be burn-in for 2 Hours under normal input and 80% rated load.
Testing Equipment
| ! NO. | Testing Equipment | Model | Remark |
|---|---|---|---|
| 1 | AC Source | Ainuo | |
| 2 | ower Meter | 8710C | |
| 3 | Electronic Load | JT6330A | |
| 4 | Oscilloscopes | MDO3014 | |
| 5 | Digital Multimeter | FLUKE 15B | |
| 6 | DC Power | IT6721 | |
| 7 | HI-POT Tester | RK7122 | |
| 8 | Cons. T/H Simulator | XINBAO |
Product Drawing
- AC Plug: UK/US/AU/EU removable plug
- DC Plug: Type-C
- DC Cable Spec: 3 wires, 18# x 2, 26# x 1, Type-C
- DC Cable Size: 1.2M
Gallery
- Product size
- EU Standard
- US Standard
- AU Standard
- UK Standard
Product Includes