==Description== | ==Description== | ||
The document details the electrical, mechanical and environmental specifications of a SMPS, the power supply | |||
provides 15W continuous output power. The power supply shall meet the RoHS requirements. | |||
==Specifications== | |||
===Input Characteristics=== | |||
* Input Voltage & Frequency | |||
{| class=wikitable | |||
|- | |||
! Parameters !!Minimum !!Rating !! Maximum | |||
|- | |||
|Input Voltage|| 90Vac || 100Vac~240Vac|| 264Vac | |||
|- | |||
|Input Frequency|| 47Hz|| 60Hz/50Hz|| 63Hz | |||
|} | |||
* Inrush Current (cold start @ 230V AC) No damage for 220V/50Hz at cold start (25℃). | |||
* Average Efficiency: Standby power <0.1W @ 230VAC/50Hz. | |||
* Cooling: Natural convection. | |||
* Mean Time Between Failure(MTBF):The MTBF for the power adapter shall equal or exceed 10,000 hours when operated at full rated load in an | |||
ambient temperature of 25 degree C. | |||
* Output Characteristics: | |||
{| class=wikitable | |||
|- | |||
! RATED OUTPUT !!colspan="2" |Rated Load !!Remark | |||
|- | |||
| || Min. || Max.|| | |||
|- | |||
|Output Voltage(unload)||<font color=red> 4.9V</font> ||<font color=red> 5.3V</font> || | |||
|- | |||
|Output Voltage(Full load) || <font color=red>4.9V</font>|| <font color=red> 5.3V</font>|| with wire testing | |||
|- | |||
|Output Current|| 0A || 3A || | |||
|- | |||
|Turn - on Delay Time|| / || 3S || | |||
|- | |||
|Hold-up Time || 5mS || / || | |||
|- | |||
|Ripple & Nosic ||/ ||150mVp-p|| | |||
|- | |||
|OCP || || || | |||
|} | |||
==Features== | ==Features== | ||
==Gallery== | ==Gallery== |
Revision as of 17:30, 7 November 2019
5V-4A UK-Standard
Description
The document details the electrical, mechanical and environmental specifications of a SMPS, the power supply provides 15W continuous output power. The power supply shall meet the RoHS requirements.
Specifications
Input Characteristics
- Input Voltage & Frequency
Parameters | Minimum | Rating | Maximum |
---|---|---|---|
Input Voltage | 90Vac | 100Vac~240Vac | 264Vac |
Input Frequency | 47Hz | 60Hz/50Hz | 63Hz |
- Inrush Current (cold start @ 230V AC) No damage for 220V/50Hz at cold start (25℃).
- Average Efficiency: Standby power <0.1W @ 230VAC/50Hz.
- Cooling: Natural convection.
- Mean Time Between Failure(MTBF):The MTBF for the power adapter shall equal or exceed 10,000 hours when operated at full rated load in an
ambient temperature of 25 degree C.
- Output Characteristics:
RATED OUTPUT | Rated Load | Remark | |
---|---|---|---|
Min. | Max. | ||
Output Voltage(unload) | 4.9V | 5.3V | |
Output Voltage(Full load) | 4.9V | 5.3V | with wire testing |
Output Current | 0A | 3A | |
Turn - on Delay Time | / | 3S | |
Hold-up Time | 5mS | / | |
Ripple & Nosic | / | 150mVp-p | |
OCP |
Features
Gallery
Package Includes
Keywords