F-0005: Difference between revisions
Jump to navigation
Jump to search
Line 6: | Line 6: | ||
The fan motor is a two-phase four-pole type and is driven by 12V. | The fan motor is a two-phase four-pole type and is driven by 12V. | ||
==Features== | ==Features== | ||
===Specifications=== | |||
{| class="wikitable" | |||
|- | |||
! Item !! Desciption !!Unit | |||
|- | |||
| Rated Voltage || DC 12 || VDC | |||
|- | |||
| Operation Voltage || DC 10.8~13.2 || VDC | |||
|- | |||
| Start-up Voltage || DC ≤6(At 25℃ power on/off) || VDC | |||
|- | |||
| Current|| 0.05±0.02 || A | |||
|- | |||
|Operation Current||0.07±0.02|| A | |||
|- | |||
|Input Power ||0.6 ||W | |||
|- | |||
|Speed (At 25℃,To record speed afler fan running normal,This time about 3~5minutes)||5500±10%||RPM | |||
|- | |||
|Air Flow(at zero static pressure)|| 4.71|| CFM | |||
|- | |||
| Air Pressure(at zero air flow) || 2.5 || mmH2O | |||
|- | |||
| Acousitical Noise (AVG.)|| 25.3|| dB(A) | |||
|- | |||
|Insulation Type || CLASS A(105°)|| NA | |||
|- | |||
! scope="col" | Insulation Strength | |||
! colspan="2" | Under the condition of 500V DC voltage, the impedance between the outer frame and the terminal line is not less than 10 Megohm | |||
|- | |||
! scope="col" | Dielectric Strength | |||
! colspan="2" | Under the condition of 600V/50Hz alternating current for one minute, the current between the outer frame and the terminal line No more than 5MA | |||
|- | |||
! scope="col" | Life Expectancy | |||
! colspan="2" | It is expected to be normal when the ambient temperature is 25℃ and the relative temperature is 15-65%RH 30,000 hours of work | |||
|- | |||
! scope="col" | Rotation | |||
! colspan="2" | counterclockwise Logo side | |||
|- | |||
! scope="col" | Lead Wire | |||
! colspan="2" | 2.5 reverse end 2468 30# black red line L=1000MM | |||
|} | |||
==Gallery== | ==Gallery== | ||
{| | {| |
Revision as of 15:41, 13 August 2020
4010 Blower
Description
4010 blower is a DC fan with the electrical and mechanical characteristics of an axial-flow brushless DC fan.
The fan motor is a two-phase four-pole type and is driven by 12V.
Features
Specifications
Item | Desciption | Unit |
---|---|---|
Rated Voltage | DC 12 | VDC |
Operation Voltage | DC 10.8~13.2 | VDC |
Start-up Voltage | DC ≤6(At 25℃ power on/off) | VDC |
Current | 0.05±0.02 | A |
Operation Current | 0.07±0.02 | A |
Input Power | 0.6 | W |
Speed (At 25℃,To record speed afler fan running normal,This time about 3~5minutes) | 5500±10% | RPM |
Air Flow(at zero static pressure) | 4.71 | CFM |
Air Pressure(at zero air flow) | 2.5 | mmH2O |
Acousitical Noise (AVG.) | 25.3 | dB(A) |
Insulation Type | CLASS A(105°) | NA |
Insulation Strength | Under the condition of 500V DC voltage, the impedance between the outer frame and the terminal line is not less than 10 Megohm | |
Dielectric Strength | Under the condition of 600V/50Hz alternating current for one minute, the current between the outer frame and the terminal line No more than 5MA | |
Life Expectancy | It is expected to be normal when the ambient temperature is 25℃ and the relative temperature is 15-65%RH 30,000 hours of work | |
Rotation | counterclockwise Logo side | |
Lead Wire | 2.5 reverse end 2468 30# black red line L=1000MM |
Gallery
Package Includes
Keywords
- 4010 blower ,DC fan,axial-flow brushless DC fan,, two-phase four-pole type fan, DC 12V Fan.