F-0005: Difference between revisions
Jump to navigation
Jump to search
| Line 6: | Line 6: | ||
The fan motor is a two-phase four-pole type and is driven by 12V. | The fan motor is a two-phase four-pole type and is driven by 12V. | ||
==Features== | ==Features== | ||
* 12V DC Fan | |||
* Long life term | |||
* Good for Heat dissipation | |||
===Specifications=== | ===Specifications=== | ||
{| class="wikitable" | {| class="wikitable" | ||
Revision as of 15:51, 13 August 2020
4010 Blower
Description
4010 blower is a DC fan with the electrical and mechanical characteristics of an axial-flow brushless DC fan.
The fan motor is a two-phase four-pole type and is driven by 12V.
Features
- 12V DC Fan
- Long life term
- Good for Heat dissipation
Specifications
| Item | Desciption | Unit |
|---|---|---|
| Rated Voltage | DC 12 | VDC |
| Operation Voltage | DC 10.8~13.2 | VDC |
| Start-up Voltage | DC ≤6(At 25℃ power on/off) | VDC |
| Current | 0.05±0.02 | A |
| Operation Current | 0.07±0.02 | A |
| Input Power | 0.6 | W |
| Speed (At 25℃,To record speed afler fan running normal,This time about 3~5minutes) | 5500±10% | RPM |
| Air Flow(at zero static pressure) | 4.71 | CFM |
| Air Pressure(at zero air flow) | 2.5 | mmH2O |
| Acousitical Noise (AVG.) | 25.3 | dB(A) |
| Insulation Type | CLASS A(105°) | NA |
| Insulation Strength | Under the condition of 500V DC voltage, the impedance between the outer frame and the terminal line is not less than 10 Megohm | |
| Dielectric Strength | Under the condition of 600V/50Hz alternating current for one minute, the current between the outer frame and the terminal line No more than 5MA | |
| Life Expectancy | It is expected to be normal when the ambient temperature is 25℃ and the relative temperature is 15-65%RH 30,000 hours of work | |
| Rotation | counterclockwise Logo side | |
| Lead Wire | 2.5 reverse end 2468 30# black red line L=1000MM | |
Gallery
Package Includes
Keywords